| General Specifications |
| Voltage Regulation |
Front / Back Panel |
| 100 Volt Mode Boost Range |
97 - 89 VAC |
Load Graph |
5 lights |
| 110 Volt Mode Boost Range |
100 - 91 VAC |
Battery Graph |
5 lights |
| 115 Volt Mode Boost Range |
103 - 93 VAC |
Battery Fault Indicator |
Light |
| 120 Volt Mode Boost Range |
108 - 96 VAC |
On Battery Indicator |
Light |
| 100 Volt Mode Buck Range |
129 - 141 VAC |
UPS Fault Indicator |
Light and Audible Alarm |
| 110 Volt Mode Buck Range |
132 - 145 VAC |
Test / Silence Button |
Light |
| 115 Volt Mode Buck Range |
135 - 148 VAC |
Site Wiring Fault Indicator |
Light (On 120V Models Only) |
| 120 Volt Mode Buck Range |
138 - 151 VAC |
Boost Indicator |
Light |
| Buck / Boost Percentage |
"10% Meets 1996 CBEMA Voltage Regulation Standards |
Buck Indicator |
Light |
| |
Overload Indicaor |
Light and Audible Alarm |
| Input/Output |
Short Circuit Indicator |
Multiple Lights and Audible Alarm |
| Normal Input voltage |
89-151 VAC |
General Fault Indicator |
All Lights and Audible Alarm |
| Normal Input Frequency |
Autoselecting "5% |
AC Acceptable Indicator |
Light |
| Input Protection |
Circuit Breaker |
Active Outlet Diagram |
4 lights |
| Output Voltage |
100/110/120 |
|
| Short Circuit Protection |
Inverter & AC Modes |
Power Management |
| Overload Shutdown |
Over 110% Shutdown in XX Minutes |
Port Type |
RS-232 |
| Output Waveform |
Sine Wave |
Intelligent Card Slot |
Available on 1100 and 1500 VA Models Only |
| Total Harmonic Distortion |
Less than 3% |
Remote Modem Slot |
Available on 1100 and 1500 VA Models Only |
| |
SNMP Card |
Available |
| Surge Suppression |
Windows Plug & Play |
Yes |
| IEEE Cat. C |
NM: 170V CM: 230V |
|
| Software Configurable Features |
| Joules / Peak KAmps |
2070 / 59 KA |
Boost Transfer Voltage |
Software Selectable |
| Net / Fax / Modem Connector Type |
RJ-45 |
Buck Transfer Voltage |
Software Selectable |
| Suppression Components |
6 MOVs, 3 Avalanche Diodes, Gas Tube |
Duration of Low Battery Warning |
2, 5, 7 or 10 minutes |
| |
UPS Shutdown Delay |
20, 180, 300 or 600 seconds |
| Noise Rejection |
Load Shed Delay by Outlet Pair |
Disable pair in 3, 6 or 9 minutes |
| Normal Mode 100 KHz |
80 dB |
Auto Start Select |
Auto Start (default) or manual start after AC restore |
| Normal Mode 1 MHz |
65 dB |
Silence Alarm Options |
5 (default) or 30 second delay, low battery, no alarm |
| Normal Mode 10 MHz |
35 dB |
Self Test Scheduling Options |
Power On and 7 day (default), POST, 7 day, None |
| Common Mode 100 KHz |
45 dB |
UPS Identification |
Up to 7 Characters |
| Common Mode 1 MHz |
48 dB |
Noise Sensitivity Select |
Normal (default), reduced or low |
| Common Mode 10 MHz |
50 dB |
Remote Switching by Outlet Pair |
Immediate turn On, Off or Reboot |
| Filtering Components |
Torroid, Capacitors |
|
| |
Enviroment / Warranty |
| UPS |
Temperature |
0 - 40 C |
| Transfer in msec |
2-4 milliseconds |
Humidity |
5-90% (non-condensing) |
| Hot-Swap Batteries |
Yes |
Audible Noise @1M (500 & 800 VA) |
40 dB |
| Recharge time to 90% |
less than 6 hours |
Audible Noise @1M (11 & 1500 VA) |
45 dB |
| UPS Self-Test Cycle |
Default: Every 7 days (User Programmable) |
Agency Approvals |
CE, VDE, CISPR, UL, TUV, CSA, FCC, ISO 9002 |
| Battery Self-Test Cycle |
Power On & Continuous |
Warranty |
5 years |