FEATURES
SATISFACTION
CONTROLLER VI
Product type/outlets/switches
Type of surge protector
Plugstrip
Power Controller
Number of proected AC outlets
6
6
Master on/off switch
1
1
Individual outlet switches
 
6
Protection options
Fax/modem protection option
RJ-11 jacks; 2 wire/1 pair; RJ-45 jacks; 8 wire/4 pair
Network protection option
Ethernet RJ-45 jacks
Harmonic noise rejection option
"PLUS" option
Undervoltage shut-off option
For copiers, printers, and devices sensitive to sags
"Green" Energy Saver option  
For monitor/printer
Rack-mount brackets option  
yes
Diagnostic lights/audible alarms
Polarity reversal fault
light/audible alarm
System integrity fault
light/audible alarm
Fax/modem protection fault
light/audible alarm
Network protection fault
light/audible alarm
Proper ground
light
Power on/off
light
Safety disconnect/Physical characteristics
Fail-safe resettable circuit breaker
12 amp
Fail-safe fuse
yes
Detachable power cord
Heavy 18-gauge steel
Maximum HxWxD dimensions (inches)
(cm)
2" x 6" x 10"
5.1 x 15.2 x 25.4 cm
2" x 14" x 11"
5.1 x 35.6 x 27.9 cm
PERFORMANCE
SATISFACTION/CONTROLLER VI
Surge Suppression
Single-surge energy absorption
1810 joules
IEEE 587/ANSI C62.41 Cat. C impulse:
(6KV/3KA impulse let-through voltage)***
170V Normal Mode
230V common mode
Clamping voltage level
200V
Peak surge current
26,500 Amps normal-mode
Calmping response time
Picoseconds (fastest response available)
Three-stage sine wave tracking
Yes
Silicon avalanche diodes/MOVs/gas tubes
Yes
Electric Power Research Institute approval
Tested/approved by US
UL 1449 approval across all 3 lines
Yes
EMI/RFI noise rejection
Normal-mode noise rejection: 250K - 5MHz
5M - 10 MHz
55-80 dB (99.8-99.9%)*
35-55 dB (98.3-99.8%)*
Common-mode noise rejection: 250K - 5MHz
5M - 10 MHz
40-50 dB (99.0-99.7%)*
50-60 dB (99.7-99.9%)*
Harmonic noise rejection
Filters from 80 Hz
Operating conditions
Nominal line voltage
100-120 VAc or 200-250 VAc, 50/60 Hz
Maximum line current (continuous)
12 Amps (6 Amps for 200-250v)
Warranty/Approvals
Ultra Lifetime connected equipment protection
$50,000**
ULtra Lifetime IPT product warranty
Yes
Agency approvals
UL 1449 (surge), UL 1283 (EMI filter)
UL 1363; CSA 22.2 (UL Certified); TUV
CE
Electric Power Research Institute
(performance/safety tested)
*Normal-mode (L to N) and common-mode (L+N to G) noise rejection performance was tested and certified by Communication Certification Laboratory, an independent EMI/RFI testing lab.
** Repair or replace up to %50K of registered an properly connected equipment damaged by electrical sure or lightning. (See warranty for details. Valid in the US and Canada only.)
*** Of the IEEE 587/ANSI C62.41 Category A, B and C tests, the CAT. C test (6KV 1.2 x 50 usec impulse) is the most rigorous because it requires the surge protector to absorb 15-30 times more impulse current and energy than the Cat. A test (6KV, 200A) and 6-12 times more than the Cat. B test (6KV, 500A).




Click here to see pricing and shipping information.


© 1997 International Power Technologies